In the Pharmaceutical & Food & beverages industries, high purity water is used in the manufacturing process. We design the system in such a way that it gets max product water & min reject water. our system guarantee compliance with USP Purified Water, EP & GMP standards manufactured with cGMP design, hygienic construction, validated performance, and robust automation, our PW system guarantees dependable microbial, chemical, and physical purity.
Compliance Standards:
Our Purified Water System meets:
- USP Purified Water Requirements
- European Pharmacopoeia (EP)
- WHO – GMP Guidelines
- FDA – cGMP expectations
- ASME BPE Hygienic Design Standard
Water Quality Achieved:
- Conductivity ≤ 1.3 µS/cm @ 25°C
- TOC ≤ 500 ppb
- Microbial Count < 100 CFU/ml
System Philosophy:
Pretreatment → RO 1st Pass → RO 2nd Pass → EDI → PW Storage Tank → Distribution Loop
This multi-barrier design ensures:
- Excellent desalination
- Removal of ionic & non-ionic impurities
- Stable microbial control
- Consistent & reliable quality
Key Features:
- 2 Pass Reverse Osmosis System
- EDI (Electrodeionization) for ultra-pure quality
- SS316L Purified Water Storage Tank
- SS316L Electropolished Distribution Loop
- Dead-leg free hygienic piping
- Ozone sanitization / chemical sanitization
- Automatic operation with PLC/SCADA
- Data logging & alarms
- Complete validation support
System Construction & Hygiene:
- Material of Construction: SS 316L
- Internal Surface Finish: Ra ≤ 0.6 µm
- Electropolished pipelines
- Orbital welding
- Hygienic Tri-clamp fittings
- Sloped piping design
- Fully drainable system
- 0.2 micron hydrophobic vent filter
- Spray ball for internal cleaning/sanitization
Automation & Control:
- PLC / HMI based operation
- SCADA with 21 CFR Part 11 (optional)
- Continuous conductivity monitoring
- Flow, pressure, temperature monitoring
- Auto start / stop
- Auto RO flushing
- Level-based operation
- Alarm management & data logging
Sanitization Philosophy:
- Ambient Loop with Ozone Sanitization (Standard)
- Chemical sanitization optional
- Hot sanitization optional (as per user requirement)
Documentation & Validation Support:
We provide full pharmaceutical documentation:
- DQ / IQ / OQ / PQ Support
- FAT / SAT
- Calibration Certificates
- Weld Qualification Documents
- MOC Certificates
- SOP Preparation Support
Why Choose Us?
- Pharma compliant design
- Reliable and validated performance
- Low operating cost
- Hygienic and robust construction
- Long service life
- Qualified engineering & service team
Compliance: USP | EP | IP | WHO-GMP | ISPE | ASME-BPE
Applications